Clarkson

Chimney Liner Installation in Santa Ana for Each Flue That Needs It

Send the Unit Count

Scope at Each Fireplace

A cracked or gapped flue lets heat and gases reach wood framing. The camera from a Level 2 shows where the liner has failed, and on a building we list which flues need relining and which do not. A stainless liner is sized to the appliance, run down the flue, insulated where needed and capped. Each liner is quoted in writing per chimney after the scan.

Camera footage shows each failed section
Stainless liner sized to the appliance
Insulation added where clearances need it
Quote written per flue after the scan

What a Failed Flue Liner Looks Like on Camera

Most masonry chimneys in older buildings are lined with clay tiles stacked inside the brick. The liner keeps heat, smoke and gases inside the flue and away from the brick and the wood framing around it. Clay tiles crack from age, from a chimney fire, and from earthquakes. Joints between tiles lose their mortar and open up, and sections can shift sideways so that the tiles no longer line up. None of this is visible from the room; it shows up on the camera during a Level 2 inspection or when a fireplace is being converted to gas. On a building with several flues, the camera often finds one or two that have failed while the rest are sound, so the liner question is answered flue by flue. A cracked liner means the fireplace should not be used until it is fixed, and we tag it that way with the unit number.

Before we quote a liner, we go through the camera footage with the owner or manager and mark exactly where the tiles have failed. Then we work out what the flue will serve. A wood fireplace staying on wood needs a liner rated for wood smoke, sized to the fireplace opening. A fireplace getting a gas insert needs a liner sized to that insert. Stainless steel liners are the usual choice because they fit inside the existing flue, can be insulated where clearances to framing are tight, and come in sizes for each appliance. Where a flue shares a stack with another, we check that the new liner does not affect the second flue. Each failed flue gets its own quote in writing listing the liner type, size and length, insulation, the top plate and cap, and any repair needed at the smoke chamber.

Installing the Liner and Closing Out the Record

Liner installation is done mostly from the roof. The old flue is swept, any loose tile pieces that would block the run are removed, and the liner is lowered from the top down to the smoke chamber or the appliance, then connected at the bottom. Insulation is wrapped on where needed. At the top, a plate seals the space between the liner and the old flue, and a cap goes on to keep rain and animals out. Inside, the fireplace or insert is connected and tested. On occupied buildings, the work is planned with the manager so the unit below knows when the crew will be in, and drop cloths cover the route to the fireplace. The fireplace stays tagged as not for use until the job is finished and tested.

When the liner is in, we run the camera through it and add the footage to the unit's record, along with the liner make, size and length, a photo of the top plate and cap, and the date. That page is what a buyer's inspector or an association will ask for when they see a relined flue. On properties where several flues need liners, we usually group them into one visit so the roof access and setup are done once, but each flue is still listed separately on the quote and in the record. In Santa Ana, Stanton and Placentia, where many older buildings have the same tile liners in every stack, the first relined flue often prompts a check of the rest, and the camera footage makes that decision simple.

How Clarkson Chimney Sweep Books a Building

Every Unit Listed

Each fireplace numbered before the visit

One Trip

All fireplaces on the list in one visit

Priced per Fireplace

Repairs quoted in writing, line by line

Records to File

A dated page with photos per fireplace

Chimney Liner Installation by city

Each city page covers this service for the building types on that part of the route.

All route cities

No route city matches. Try a neighboring one, or send the address.

Other Services by the Unit

Chimney Sweep

Each flue on the property brushed and vacuumed in unit order, with a cleaning record filed per fireplace.

See the scope

Chimney Inspection

Level 1, 2 or 3 inspections under NFPA 211 for every chimney on a property, with a dated report per flue.

See the scope

Chimney Repair

Repairs listed by unit and ranked by urgency, so an owner can schedule a whole building's work in one pass.

See the scope

Fireplace Inspection

Firebox, damper, hearth, glass and clearances checked in every unit, with one page per fireplace for the file.

See the scope

Fireplace Repair

Cracked firebrick, stuck dampers and smoking openings fixed across units, each repair logged against its unit number.

See the scope

Chimney Level 2 Inspection

A video scan through each flue, called for after a sale, a quake or a chimney fire, recorded unit by unit.

See the scope

Chimney Cap Installation

Stainless caps measured flue by flue, so every stack on the roof keeps out rain, birds and embers.

See the scope

Chimney Flashing Repair

Leaks at the roof line traced to flashing, crown, brick or cap, chimney by chimney, before any repair is priced.

See the scope

Chimney Masonry Repair

Mortar joints, spalled brick and worn crowns repaired across a building's chimneys, with mortar matched to the old.

See the scope

Chimney Rebuilds

Partial or full rebuilds when repairs would not hold, with the evidence for each chimney shown before any quote.

See the scope

Fireplace Cleaning

Ash, soot and smoke stains cleared from fireboxes, glass doors and hearths, unit after unit, in one booking.

See the scope

Gas Fireplace Cleaning

Burners, pilots, logs, glass and vents cleaned on every gas unit in a building, with a carbon monoxide test each.

See the scope

Gas Fireplace Repair

Pilots that drop out, igniters that click and weak flames diagnosed part by part, with each fix logged by unit.

See the scope

Fireplace Remodel

Surrounds, mantels and hearths redone around clearance rules, for one main room or a run of matching units.

See the scope

Fireplace Inserts

Sealed gas, wood or electric inserts that turn an open firebox into a heater, fitted unit by unit.

See the scope

Pellet Stove Repair

Augers, igniters, blowers and control boards tested link by link until the stove feeds and burns again.

See the scope

Wood Stove Repair

Door gaskets, firebrick, baffles, combustors and stovepipe replaced with parts matched to the make and model.

See the scope

Gas Logs

Vented or ventless gas log sets sized to each firebox, lit and leak-tested before the unit is handed back.

See the scope

Chimney Seismic Retrofit

Bracing, straps or a rebuild to the roofline for brick chimneys at risk in a quake, assessed stack by stack.

See the scope

Chimney Crown Repair

Cracked or crumbling concrete crowns patched, sealed or recast so water stops entering the top of the stack.

See the scope

Dryer Vent Cleaning

Lint cleared from dryer ducts in each unit or laundry room, with airflow measured before and after.

See the scope

Chimney Leak Repair

Water in a unit traced to its source at the chimney, fixed, and logged so the same leak cannot return unnoticed.

See the scope

Chimney Waterproofing

Breathable water repellent applied to brick chimneys after repairs, so the masonry sheds rain instead of soaking it up.

See the scope

Chimney Damper Repair

Rusted, stuck or warped dampers repaired or replaced so each fireplace closes tight and opens fully.

See the scope

Chimney Chase Cover

Rusted or pooling metal chase tops on factory-built chimneys replaced with stainless covers that shed water.

See the scope
Call (657) 213-7314